Licence number: 217
Annual Return Start: 01 Oct 2012
Annual Return End: 30 Sep 2013
Date Received: 27 Nov 2013
 
Licence Condition numberType of non-complianceEPA actionsNo. of times occurred
O1 Dry weather discharges occurred from a directed overflow structure, caused by the incorrect placement of the high level well float alarm & a malfunctioning level sensor in the WWPS. Promptly responded, made repairs & cleaned up overflow area EPA to monitor future compliance with this condition 10
O1.1 A portion of inflows less than 65L/s were discharged without receiving ultra violet disinfection due to system failure. Flows were diverted to the storage pond, the EPA notified & fault was repaired. Sampling undertaken. Procedures modified. EPA to monitor future compliance with this condition 1